Lead Time: 4-7 Weeks
Biological Safety Cabinet Class II A2-1200LC
Explore the features and benefits of the Biological Safety Cabinet Class II A2 for safe handling of infectious agents and toxins.
A biological safety cabinet (BSC) is a primary engineering control used to protect personnel against biohazardous or infectious agents.
It is also to help maintain quality control of the material being worked with as it filters both the inflow and exhaust air
Biological Safety Cabinet Class II A2
A biosafety cabinet is designed to provide both a clean work environment and protection for:
– employees who create aerosols when working with infectious agents or toxins.
A Hi-Safe and Smart Biosafety Cabinet
– CE/ISO9001/ISO12485/EN12469/NSF/CFDA certified, registration certificate of China Medical Device
– Double airflow monitoring sensors to ensure stable airflow speed: Inlet 0.53m/s, vertical 0.35m/s
– Intuitive German-made EMB fan motor sensitively reacts to interior air pressure change
– Double ULPA filters with with life indicator, 99.9995% filtration efficiency against 0.12 micron meter particules
Model
|
HFsafe-1200LC
|
Nominal Size
|
1.2 meters(4′)
|
External Dimensions with Base Stand (WxDxH)
|
1340x790x2130 mm 52.8″x 31.1 “x83.9”
|
Internal Work Area, Dimensions (WxDxH)
|
1250x575x625mm 49.2″x22.6″x24.6″
|
Average Airflow Velocity*
|
|
Inflow
|
Filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns
|
Downflow
|
Filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns
|
Airflow Volume
|
|
Inflow
|
477m3/h(281cfm)
|
Downflow
|
945m3/h(556cfm)
|
Exhaust
|
477m3/h(281cfm)
|
ULPA Filter Typical Efficiency
|
|
Downflow
|
Filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns
|
Exhaust
|
Filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns
|
Biosafety Protection Test
|
|
Personnel Protection Test
|
Kl-Discus containment and microbiological testing is performed
|
Product Protection Test 1~8X106
|
≤5CFU
|
Cross-contamination Test 1-8×106
|
≤2CFU
|
Fluorescent Light Intensity
|
≥650Lux (foot candles)
|
Excellent light distribution
|
Yes
|
RMS
|
≤5µm
|
Cabinet Construction
|
|
Main Body
|
Steel with white oven-baked epoxy-polyester
|
Work Zone
|
Stainless steel, type 304
|
Side Walls
|
Stainless steel, type 304
|
Window material
|
Hardened/laminated safety glass
|
Power Supply*
|
|
220V/50Hz
|
Yes
|
220V/60Hz
|
Yes
|
110V/60Hz
|
Yes
|
Biological Safety Cabinet Class II A2