Heating / Cooling Circulating Baths
Lead Time: 4-6 Weeks
Used to maintain the temperature of products.
They are used in manufacturing processes that require precise temperature control, such as the production of chemicals, pharmaceuticals, and plastics.
Used in the food and beverage industry to maintain the temperature of products.
Features:
* Using environmentally friendly CFC-free refrigeration technology to meet the requirements of environmental protection.
* Using high-quality full-enclosed air-cooled compressor cooling system, low noise
* Full-enclosed air-cooled compressor cooling system with thermal overload protection automatically
* with a power-off protection function, automatically delayed for three minutes
* using a TFT touch screen, easy to understand working condition
* Intelligent PID automatically adjust control function
* Upper and lower temperature alarm can be set
* with over heat alarm system to ensure the safety apparatus
* Inner high-quality stainless steel material
* with external circulating pump, can be established the second constant temperature field outside the bath
* Cold liquid can be cited outside the tank, cooling the experimental container outside the bath
* Using analogue theory, automatic identify the difference between set temperature and the ambient temperature, to confirm
whether a single heating or cooling heating work simultaneously to achieve the energy saving
* Using high-quality full-enclosed air-cooled compressor cooling system, low noise
* Full-enclosed air-cooled compressor cooling system with thermal overload protection automatically
* with a power-off protection function, automatically delayed for three minutes
* using a TFT touch screen, easy to understand working condition
* Intelligent PID automatically adjust control function
* Upper and lower temperature alarm can be set
* with over heat alarm system to ensure the safety apparatus
* Inner high-quality stainless steel material
* with external circulating pump, can be established the second constant temperature field outside the bath
* Cold liquid can be cited outside the tank, cooling the experimental container outside the bath
* Using analogue theory, automatic identify the difference between set temperature and the ambient temperature, to confirm
whether a single heating or cooling heating work simultaneously to achieve the energy saving
Heating / Cooling Circulating Baths
Model
|
Temperature Range/solution (±0.1℃)
|
Inner Size(mm) / Volume (L)
|
Pump Flow(L/min)/
Pump Pressure(bar) |
SDC-6
|
-5-100℃
|
260*200*140 /7
|
0-15 / 0.45
|
DC-1006
|
-10-100℃
|
260*200*140 /7
|
0-15 / 0.45
|
DC-2006
|
-20-100℃
|
260*200*140 /7
|
0-15 / 0.45
|
DC-3006
|
-30-100℃
|
260*200*140 /7
|
0-15 / 0.45
|
DC-4006
|
-40-100℃
|
260*200*140 /7
|
0-15 / 0.45
|
DC-0510
|
-5-100℃
|
260*200*200 /10
|
0-15 / 0.45
|
DC-1010
|
-10-100℃
|
260*200*200 /10
|
0-15 / 0.45
|
DC-2010
|
-20-100℃
|
260*200*200 /10
|
0-15 / 0.45
|
DC-3010
|
-30-100℃
|
260*200*200 /10
|
0-15 / 0.45
|
DC-4010
|
-40-100℃
|
260*200*200 /10
|
0-15 / 0.45
|
DC-0515
|
-5-100℃
|
300*250*200 /15
|
0-15 / 0.45
|
DC-1015
|
-10-100℃
|
300*250*200 /15
|
0-15 / 0.45
|
DC-2015
|
-20-100℃
|
300*250*200 /15
|
0-15 / 0.45
|
DC-3015
|
-30-100℃
|
300*250*200 /15
|
0-15 / 0.45
|
DC-4015
|
-40-100℃
|
300*250*200 /15
|
0-15 / 0.45
|
DC-2020
|
-20-100℃
|
300*250*260 /20
|
0-15 / 0.45
|
DC-0530
|
-5-100℃
|
440*325*200 /30
|
0-15 / 0.45
|
DC-1030
|
-10-100℃
|
440*325*200 /30
|
0-15 / 0.45
|
DC-2030
|
-20-100℃
|
440*325*200 /30
|
0-15 / 0.45
|
DC-3030
|
-30-100℃
|
440*325*200 /30
|
0-15 / 0.45
|
DCW-1015
|
-10-100℃
|
280*250*220 /15
|
0-15 / 0.45
|
DCW-2008
|
-20-100℃
|
280*250*140 /10
|
0-15 / 0.45
|
DCW-3506
|
-35-100℃
|
260*200*140 /7
|
0-15 / 0.45
|
DCW-3510
|
-35-100℃
|
250*200*200 /10
|
0-15 / 0.45
|
DCW-0506
|
-5-100℃
|
260*200*140 /7
|
0-15 / 0.45
|
DCW-4006
|
-40-100℃
|
260*200*140 /7
|
0-15 / 0.45
|